The sensor is designed assuming constant current drive, but it can also be driven at constant voltage.
It’s possible, but with reduced sensitivity.
It can not be used.
Although it differs for each pressure range, it is ±0.3 to ±1.5% F.S.
There is no pressure sensor with built-in IC.
It is not in our lineup.
The withstand pressure for 100kPa is up to 10 times the rated pressure.
For other pressure ranges, it is 3 to 8 times.
Storage temperature range: -40°C to +125°C Operating temperature range: -20°C to +100°C
Since it is an analog output, the resolution is infinite.
Atmospheric pressure is the standard.
It can not be used. If it freezes, it will not be covered by compensation.
It can not be used. Not covered by compensation.
Since it is a gauge pressure sensor, it cannot be used in a closed environment.
Open the air inlet when using.
Although it differs for each pressure range, it is ±0.2 to ±0.5% F.S.
Although it differs for each pressure range, it is ±0.2 to ±0.5% F.S.
The accuracy display %FS is the value converted to 100% of the output voltage at the rated pressure.
Therefore, the conversion to kPa can be calculated by “Rated pressure x %FS”.
For example, when converting the rated pressure 98.1kPa±0.3%FS, it will be ±98.1kPa x 0.003 = ±0.2943kPa.
Packing shape is stick or tray.
The packing tray is a dedicated tray that supports mounter mounting.
We don’t have absolute pressure sensor. Our pressure sensor is only gauge pressure sensor.
It can also be used with constant voltage drive. However, sensitivity fluctuation is larger than constant current drive.
The total accuracy is the linearity and pressure hysteresis at room temperature plus the characteristic fluctuations in the operating temperature range (offset voltage temperature characteristics + sensitivity temperature characteristics).
Refers to the output span voltage. When showing error and accuracy, it is indicated as a percentage of full scale.
Gauge type pressure sensors detect differential pressure against atmospheric pressure. Therefore, the pressure sensor output is not affected by atmospheric pressure fluctuations.
* Accurate pressure detection cannot be performed if the atmospheric pressure inlet provided on the side of the pressure sensor package is blocked.
It is assumed that the detection medium of the single pressure sensor is “non-corrosive gas”.
Module support and custom support are possible. Please contact us here.
* However, it is limited to Japan.