〈Features〉
Developed for detecting the water level of water heaters, this sensor can detect water level and water pressure of tap water, hot water, etc. Equipped with a semiconductor pressure sensor, it has excellent linearity and reproducibility.
〈Purpose〉
Water heater, etc.
Part Number | KH2636-01 | KH2636-02 | KH2636-03 | KH2636-04 | unit | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Item | min | typ | max | min | typ | max | min | typ | max | min | typ | max | ||
Operating range |
Water level |
-2 | – | +5 | -4 | – | +5 | -2 | – | +4 | -5 | – | +7 | m |
Pressure | -19.6 | – | +49 | -39.2 | – | +49 | -19.6 | – | +39.2 | -49 | – | +68.6 | kPa | |
Zero point output voltage |
1940 | 2000 | 2060 | 2428 | 2500 | 2572 | 2147 | 2200 | 2253 | 2398 | 2458 | 2518 | mV | |
Operating maximum output voltage |
4440 | 4500 | 4560 | 4303 | 4375 | 4447 | 4547 | 4600 | 4653 | 4440 | 4500 | 4560 | mV | |
Operating minimum output voltage |
940 | 1000 | 1060 | 928 | 1000 | 1072 | 947 | 1000 | 1053 | 940 | 1000 | 1060 | mV | |
Zero point temperature characteristic(0〜50℃) |
– | – | 30 | – | – | 23 | – | – | 30 | – | – | 26 | mV | |
Sensitivity |
51 | 38.3 | 61.2 | 29.8 | mV/kPa | |||||||||
5 | 3.8 | 6 | 2.9 | mV/cm | ||||||||||
Catalog DL | PDF(1MB) |